PERMATEX INDUSTRIAL -- SPRAY-A-GASKET (R) HIGH TACK ADHESIVE SEALANT 80065 -- 8030-00-689-5646
===================== Product Identification =====================
Product ID:SPRAY-A-GASKET (R) HIGH TACK ADHESIVE SEALANT 80065
MSDS Date:01/04/1993
FSC:8030
NIIN:00-689-5646
=== Responsible Party ===
Company Name:PERMATEX INDUSTRIAL
Address:705 NORTH MOUNTAIN ROAD
City:NEWINGTON
State:CT
ZIP:06111
Country:US
Info Phone Num:203-278-1280
Emergency Phone Num:203-278-1280
Preparer's Name:STEPHEN REPETTO
CAGE:DO527
=== Contractor Identification ===
Company Name:LOCTITE CORPORATION
Address:1001 TROUT BROOK CROSSING
Box:City:ROCKY HILL
State:CT
ZIP:06067-3910
Country:US
Phone:860-571-5100
CAGE:05972
Company Name:PERMATEX INDUSTRIAL CORP; LOCTITE CORP
Address:30 TOWER LANE; AVON PARK SOUTH
Box:11915
City:AVON
State:CT
ZIP:06001
Phone:203-677-7727
CAGE:DO527
============= Composition/Information on Ingredients =============
Ingred Name:ACETONE (SARA 313) (CERCLA)
CAS:67-64-1
RTECS #:AL3150000
Fraction by Wt: 30-35%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:750 PPM; 1780 MG/M3
ACGIH TLV:750 PPM; 1800 MG/M3
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:PROPANE
CAS:74-98-6
RTECS #:TX2275000
Fraction by Wt: 35-40%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM; 1800 MG/M3
ACGIH TLV:ASPHYXIANT
Ingred Name:METHYLENE CHLORIDE (SARA 313) (CERCLA)
CAS:75-09-2
RTECS #:PA8050000
Fraction by Wt: 10-15%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:500 PPM
ACGIH TLV:50 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:HYDROCARBON RESIN
Fraction by Wt: 5-15%
Other REC Limits:NONE RECOMMENDED
Ingred Name:ISOBUTANE
CAS:75-28-5
RTECS #:TZ4300000
Fraction by Wt: 5-10%
Other REC Limits:NONE RECOMMENDED
Ingred Name:ETHYL ACETATE (CERCLA) (VAPOR PRESSURE 82 MM HG)
CAS:141-78-6
RTECS #:AH5425000
Fraction by Wt: 1-5%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:400 PPM; 1400 MG/M3
ACGIH TLV:400 PPM; 1400 MG/M3
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:N-HEXANE (CERCLA)
CAS:110-54-3
RTECS #:MN9275000
Fraction by Wt: 1-5%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:50 PPM; 180 MG/M3
ACGIH TLV:50 PPM; 176 MG/M3
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Ingred Name:TOLUENE (SARA III) (CERCLA)
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: 1-5%
Other REC Limits:* (SKIN)
OSHA PEL:100 PPM;STEL 150 PPM
ACGIH TLV:50 PPM 188 MG/M3 *
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:VOC (EPA METHOD 24): 88.0% (MAXIMUM)
RTECS #:9999999VO
Other REC Limits:NONE RECOMMENDED
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:-40F,-40C
Lower Limits:1.8
Upper Limits:12
Extinguishing Media:CARBON DIOXIDE, WATER FOG, DRY CHEMICAL
Unusual Fire/Explosion Hazard:CANS MAY EXPLODE IN FIRES.
============= Exposure Controls/Personal Protection =============
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:-40 TO 134F
Vapor Pres:56 PSIG
Vapor Density:4.0
Spec Gravity:0.7
Evaporation Rate & Reference:MORE THAN 23 (ETHER=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:RED LIQUID, SOLVENT ODOR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS; METHYLENE CHLORIDE MAY REACT WITH ACTIVE METALS UPON
PROLONGED CONTACT.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.